SP-2 Solder paste wetting tester
SP-2 is wettability testing machine for solder paste, parts electrode and PC board, adopted SP-Tension-Method (Temperature Profile Method)

Product specifications:
| Item | Specifications | |
|---|---|---|
| Load Sensor | Principle | Electro - balance sensor |
| Measurement range | 10.00gf~-5.00gf | |
| Measurement accuracy * | ± (10mgf + 1 digit) | |
| Resolution | Less than 900 mgf: 0.001 gf More than 900 mgf: 0.005 gf | |
| Temp. Sensor | Measurement range | 0~300℃ |
| Measurement accuracy | ±3℃ | |
| Heater unit | Temp. of heater unit | Room temperature ~ 300℃ |
| O2 Concentration | Simple closed heater unit with nipple for N2 purge test | |
| Temp. profile setting | 1. Preheat temp. | |
| 2. Preheat time | ||
| 3. The rate of temp. rise 3℃ /sec. (standard) | ||
| 4. Maximum temp. | ||
| 5. Maximum temp. time | ||
| Melting point | Preset solder paste melting point | |
| Table movement | Automatic: operated by PC | |
| Manual: operated by Up/Down switch (selectable 3 steps speed) | ||
| Digital output | RS-232C cable (Malcom format) | |
| Air supply | Original air pressure: 0.2~0.5 Mpa (Approx. 2~5 kgf / cm2) | |
| Adjustment air: 0.2 Mpa (Approx. 2kgf / cm2 ) | ||
| Power supply | AC100V 50 / 60Hz 700W | |
| Weight | Approx. 20kg |
*Load sensor accuracy is not concerned oscillation.