RCX-O reflow ellenőrző memória egység (O2 koncentráció ellenőrző)

fose1
    • Oxigénkoncentráció ellenőrzésére a kemencében.

Termék specifikácó:

Item Specification
Model NameRCX-O
Main UnitRCM-O
Max. measuring timeNi-MH battery: Approx. 40min.
Sampling time0.05sec. 0.1sec. 0.2sec. 0.5sec. 1.0sec. 2.0sec. 4.0sec. 8.0sec.
Arbitrary setup possible (synchronized to RCM-S memory unit)
OxygenMeasurement principleZirconia limiting current method
Measurement range50ppm~5000ppm
Measurement accuracy50ppm~1000ppm±5%FS
1000ppm~5000ppm±10%FS
Power supplySupplied from RCM-S Memory unit
Ni-MH battery (AAA battery x 3)
Outer dimensions65(W)×383(D)×25(H)(㎜) Excluding projections
WeightApprox. 950g (including battery, tray is not included)

* The maximum measuring time is a time in which heat resistance is not considered, and it cannot be measured in the reflow oven.

* Manganese batteries and alkaline batteries are not available.

* Lithium-ion secondary battery or AAA battery is selectable at the time of order.

* The above specifications are subject to change without notice.

Cooling unit:

Item Specification
Model nameRCF-3
Power supply100V~240V AC, (approx. 15W) 50/60Hz
FanSquare 120 mm (2.9 m3 /min. Max.) 2 pcs.
Input gasRc 1/8 screw connection Air 0.5Mpa following
Outer dimensions350(W)×240(D)×160(H) (㎜)
WeightApprox. 5kg
PNG_RGB